Mechanical design of the recirculating, terminal pumping in the Lund Pelletron, and experimental experience

Author

  • Ragnar Hellborg
  • Kjell Hakansson
  • Mikko Faarinen
  • Madis Kiisk
  • Per Persson
  • Göran Skog
  • Kristina Stenström

Summary, in English

A recirculating terminal pumping system has been installed in the 3 MV Pelletron tandem accelerator in Lund. An extremly limited space in the high voltage terminal and the absence of electrical power in the terminal, forced us to provide a unique design for the installation and powering of the new pumps. Details of the technical design, as well as experience of the use of the new system for accelerator mass Spectrometry, will be given.

Department/s

  • Nuclear physics
  • Quaternary Sciences

Publishing year

2002

Language

English

Pages

725-737

Publication/Series

Pramana - Journal of Physics

Volume

59

Issue

5

Document type

Conference paper

Publisher

Indian Academy of Sciences

Topic

  • Geology

Keywords

  • Pelletron
  • electrostatic accelerator
  • accelerator mass spectrometry
  • AMS
  • terminal pumping system

Conference name

Ninth International Conference on Heavy Ion Accelerator Technology (HIAT 2001)

Conference date

2002-01-14 - 2002-01-18

Conference place

New Delhi, India

Status

Published

Research group

  • AMS, Nuclear Physics

ISBN/ISSN/Other

  • ISSN: 0973-7111
  • ISSN: 0304-4289